Final Control Elements & Instrumentation Products

 

 

 

 

 

Snort Valves

 

 

 

 

 

Installed in the cold blast line of the stove in the steel plants. The valve has a blow off device. This is used to regulate the cold blast quantity which is being supplied to stoves, without creating the back pressure on the blower, as the excess air is blown away through a blow off device which is mechanically interlinked with the main valve for proportionate opening / closing.

 

Features

 

 

 

 

 

Sizes

:

500mm and above

Temperature

:

Up to 300ºC

Pressure

:

Up to 600 Kpa

Media  

:

Air

 

Material specification

 

 

 

 

 
Material of Construction :
 

Construction: Fabricated design.

Body

-

Carbon steel

Disc

-

Carbon steel

Flanges

-

Carbon steel

Shaft

-

Alloy

 

Drive : Electrical/Pneumatic.

Applications : Installed in the cold blast line of the stove in the steel plants. The valve has a blow off device. This valve is used to regulate the cold blast quantity which is being supplied to stoves, without creating the back pressure on the blower, as the excess air is blown away through a blow off device which is mechanically interlinked with the main valve for proportionate opening/closing.

Special Features : The valve is supplied with a specially designed acoustic silencer to ensure that the noise level is within acceptable limits.